Festo Электромотор MTR-DCI User Manual
Page 134
![background image](/manuals/464459/134/background.png)
A. Technical appendix
A-14
Festo P.BE-MTR-DCI-IO-EN en 1209d
Parameters
MTR-DCI-32
MTR-DCI-42
MTR-DCI-52
MTR-DCI-62
Feed
1)
DMES-18:
1500 [μm/rot]
DMES-25:
2500 [μm/rot]
DMES-40:
4000 [μm/rot]
DMES-63:
6000 [μm/rot]
Enc
2)
300 x 4 = 1200
[incr/rot]
500 x 4 = 2000 [incr/rot]
Gear
3)
MTR-DCI-...-G7 (6.75:1)
} 27:4
MTR-DCI-...-G14 (13.73:1)
} 3969:289
MTR-DCI-...-G22 (22.2:1)
} 1710:77
1)
Feed constant: dependent on the axis type, here DMES
2)
Encoder resolution on the MTR-DCI: pulse quadruplication by digital interpolation
3)
Gear reduction: specification in 2 natural numbers for the numerator or denominator of the frac-
tion
Tab. A/5:
Base parameters for the measuring system
Drive
Conversion factors UF
Increments
{ } Millimetre
Increments = millimetres*UF
Millimetres = increments/UF
Increments
{ } Inch
Increments = inches*UF
Inches = increments/UF
MTR-DCI-32...
(+DMES-18)
-G7
-G14
5400
10986.851211
13716
27906.602076
MTR-DCI-42...
(+DMES-25)
-G7
-G14
5400
10986.851211
137160
27906.602076
MTR-DCI-52...
(+DMES-40)
-G7
-G14
3375
6866.782007
85725
17441.626298
MTR-DCI-62...
(+DMES-63)
-G7
-G14
-G22
2250
4577.854671
7402.597403
57150
11627.750865
18802.597403
Tab. A/6:
Special conversion factors for the MTR-DCI with DMES