beautypg.com

Pulsafeeder Pulsar DLCM User Manual

Page 88

background image

82

7.6.2 Repeating

A Repeating Batch will start at a specified time and run for a specified duration. It will stop for a
specified period of time and then repeat the run time. This will continue indefinitely (refer to
Figure 22).

Any of the three batches can be specified as one time only or repeating.

Figure 22. Repeating Batch.

7.6.3 Overlapped

The batches can also be overlapped (refer to Figure 23 below).

Figure 23 – Overlapping Batch.

When the batches are overlapped, the flow rates are NOT additive. The highest of the two or three
flow rates is used.

The DLCM can make a 1% per second adjustment of pump stroke length. Remember that when a
batch starts, the DLCM will require some amount of time to achieve the new stroke setting. The
adjustment time is taken as a portion of the batch running time. This will cause the output of the
pump to be skewed.