13.2 DLCM Replacement

™

The following procedure assumes that you have received your replacement DLCM and are ready to
perform the replacement.

1. If possible, activate the PULSAR motor and adjust the stroke setting in the range of 10 to 90%.

Avoid 0 and 100% stroke settings on the PULSAR when replacing a DLCM. If necessary, use the
Manual Adjustment knob. It should be easier to adjust the stroke manually in the (+) counter clockwise
direction.

Do not adjust the stroke setting beyond the 100% (25 turns from 0%) setting.

2. Disconnect the power to the DLCM at the main. Power down all attached equipment (e.g., PLC's).
3. Remove the four screws and Teflon Gaskets that hold the wiring access cover to the DLCM (refer to

Figure 26).

Figure 26 – Wiring Cover Access

4. Remove the Wiring Access Cover