14. Pressing [ENTER] on the last position will cause the {CONFIRM CHANGE? / YES} screen to be

displayed. Press [ENTER] to accept. Your 1-point calibration is now complete.

Refer to Section7 – General Operation: Calibration, Pump Flow for more detailed instructions on
how to perform DLCM calibration.

6.1.9 Analog Input Calibration.

If you are not using the 0-20mA input to the DLCM for control, skip this section. To calibrate the
Input Current you must first correctly wire an external signal source. Refer to Section 5 – Installation:
Low Voltage Input Connections, Analog Input
. To perform a calibration, the signal generating device
(e.g., PLC) must be powered up and capable of altering its output from minimum to maximum signal.

6.1.9.1

One – Signal Analog Input Calibration

™

The following is a minimal procedure for calibrating the Analog Input if the 1 – Signal option is to be

used.

1. Press [CAL]. The {CALIBRATE / PUMP FLOW} screen is displayed.
2. Press [UP]. The {CALIBRATE / ANALOG IN} screen is displayed.
3. Press [ENTER]. The {0% = 4.0mA / 100% = 20.0mA} screen is displayed. These values represent the

previous calibration.

4. Press [ENTER]. The {INPUT ANALOG MIN / 0% = XXmA} screen is displayed. Adjust your PLC

to output a minimum signal (i.e., 4.0mA). The DLCM display will update as the incoming signal
changes.

5. When the displayed value stabilizes, press [ENTER] to accept it. The {INPUT ANALOG MAX /

100% = XXmA} screen is displayed. Adjust your PLC to output a maximum signal (i.e., 20.0mA).
Again, the DLCM display will update with the changing signal.

6. When the displayed value stabilizes, press [ENTER] to accept it. The {INPUT RATIO / 100% =

XX.XmA} screen is displayed.

7. Press [ENTER] to accept the 100% Ratio setting. The {CONFIRM CHANGE? / YES} screen is

displayed.

8. Press [ENTER]. Analog input calibration is now complete.

Refer to Section 7-General Operation: Analog Input Signal Calibration for more detailed instructions
on how to perform Analog Input calibration.

6.1.9.2

Two – Signal Analog Input Calibration

To calibrate a 2 Signal Analog Input, the DLCM factory default must first have been changed from
{STROKE & SPEED / 1-SIGNAL} to {STROKE & SPEED / 2-SIGNALS}. Refer to Section 7 –
General Operation:
{–MENU– / Analog Mode}
for information on configuring the Analog Mode.

™

The following is a minimal procedure for calibrating the Analog Input if the 2 – Signals option is to

be used.

1. Press [CAL]. The {CALIBRATE / PUMP FLOW} screen is displayed.
2. Press [UP]. The {CALIBRATE / ANALOG IN} screen is displayed.
3. Press [ENTER]. The {CALIBRATE / STROKE POSITION} screen is displayed.
4. Press [ENTER]. The {0% = 4.0mA / 100% = 20.0mA} screen is displayed. These values represent the

previous calibration.

5. Press [ENTER]. The {INPUT ANALOG MIN / 0% = XXmA} screen is displayed. Adjust your PLC

to output a minimum signal (i.e., 4.0mA). The DLCM display will update as the incoming signal
changes.