Page 86: One time only, 3 units

background image

80

Press [UP] to change the value to {YES}. Press [ENTER] to accept your selection. The following
message is displayed:

PLEASE WAIT

5. The first screen displayed during the Re-Set procedure prompts you to turn the motor on.

TURN MOTOR ON

TESTING ENCODER

6. Press [MOTOR].

You will hear the pump motor spin up, and the DLCM will perform an Encoder test (displaying the
following message:)

PLEASE WAIT

TESTING ENCODER

When the Encoder test is complete, (usually takes about 2 or 3 seconds) the DLCM performs a Zero
Calibration (displaying the following message:)

PLEASE WAIT

CALIBRATING ZERO

When the Zero Calibration is complete, you are returned to the {–MENU– / FACTORY DEFAULTS}
screen.
Press [MENU] and the next screen displayed is:

MOTOR STOPPED

Re-establish any Menu and Calibration settings that are non-standard at this time..

7.3 Units

By pressing [UNITS] with the motor on, the display will scroll through the CMH, GPH, LPH, CCH,
CMM, GPM, LPM, CCM, % flow, % stroke length or % motor speed. The DLCM will automatically
convert the motor and stroke settings based on the calibrated flow, to the above referenced units.

The accuracy of the flow rate display is dependent on the pump flow calibration accuracy.