End point set up – Pulsafeeder Pulsar DLCM User Manual
Page 60
54
The STROKE & SPEED output actually represents
Calibrated Flow
where 0% flow may not
correlate to 0% stroke position.
Press [ENTER] to accept this selection. You are then returned to the {–MENU– / ANALOG
OUTPUT} screen.
2. If the desired mode is {STROKE POSITION}, press [UP], and the {STROKE POSITION} screen is
displayed.
ANALOG OUTPUT
STROKE POSITION
The STROKE output actually represents
Calibrated Stroke Position
where 0% Analog output may
not correlate to the mechanical 0% stroke position.
Press [ENTER] to accept your selection. You are then returned to the {–MENU– / ANALOG
OUTPUT} screen.
3. If the desired mode is {MOTOR SPEED}, press [UP] until the {MOTOR SPEED} screen is displayed.
ANALOG OUTPUT
MOTOR SPEED
The MOTOR SPEED output represents the Target
Motor
speed.
Press [ENTER] to accept your selection. You are then returned to the {–MENU– / ANALOG
OUTPUT} screen.
7.2.7 Motor Speed Display
This sub-menu allows you to view the target and actual averaged motor speed. The average value
represents the last 30 pump strokes or less.
Motor Speed Display activation.
1. Press [MENU] to enter the {–MENU–} sub-system. Press [UP] or [DOWN] until {–MENU– /
MOTOR SPEED} is displayed.
-MENU-
MOTOR SPEED
2. Press [ENTER] to display the {TARGET RPM / ACTUAL RPM} screen.
TARGET RPM XXXX
ACTUAL RPM XXXX
Pressing [UP] or [DOWN] resets the {ACTUAL RPM} average to 0. The pump must complete 1
stroke before an actual RPM is displayed.
3. Press [ENTER] to return to the {–MENU– / MOTOR SPEED} screen.