7. If the pin number is not correct or you don’t want the selected security level, press [UP] to change the

display to {CONFIRM CHANGE? / NO}

CONFIRM CHANGE?

NO

Press [ENTER] to reject the security changes.

8. The menu display returns to {–MENU– / SECURITY} screen.

Remembering the PIN # you set, is probably one of the most important functions of setting security.

7.2.19 Number Format

The meaning of the comma and decimal point can be interchanged in the number format menu. You
can also change the number of significant decimal places.

Refer to the table in Section 10 – Factory Defaults for factory decimal position settings.

™

Number Format Set Up Procedure

1. Press [MENU]. Press [UP] or [DOWN] until the display reads {–MENU– / NUMBER FORMAT}.

Press [ENTER] to continue into the number format sub-menu.

2. The display shows the English numerical format of 9,999.99. Press [UP] to change to the European

format of 9.999,99.

e.g.: 9,999.99

DECIMAL OR COMMA

Press

[UP]

e.g.: 9.999,99

DECIMAL OR COMMA

Press [ENTER] to accept the displayed format.

3. The decimal position screen is displayed. Press [DOWN] to move the decimal position one place to the

left. Press [UP] to move the decimal position one place to the right. For example, the screen displays
9.99999, pressing [DOWN] causes the display to change to 0.999999. The valid range is 999.999 to
0.0999999. When the decimal position satisfies your needs press [ENTER] to accept.

e.g.: 9.99999

DECIMAL POSITION

Press

[DOWN]

e.g.: 0.999999

DECIMAL POSITION

4. The display returns to {–MENU– / DECIMAL FORMAT} screen.

Perform a pump flow calibration after changing the decimal position.