ENCODER ERROR

Symptom

Probable Cause

Possible Solution

Encoder defective.

Contact Technical Services
Broken or jammed gears – contact Technical
Services.

Internal Motor unable to turn adjustment
knob.

Defective motor – contact Technical Services.
Defective Drive circuits – contact Technical
Services.

Message:
{ENCODER
ERROR /
PRESS
ENTER}
displays during
encoder test.

Defective encoder or wiring

11.1.1 Encoder Diagnostics

Whenever the DLCM is re-calibrated it optionally first performs a Zero Calibration . The first portion of
the {CALIBRATING ZERO} routine is the encoder test. The DLCM will increase the stroke adjustment
one full rotation of the encoder gear train (approximately one half turn of the Manual Adjustment Knob),
while monitoring the encoder output. It will then reverse direction and drive the mechanism to the 0%
position. During this cycle, the DLCM reads the encoder output and compares it to an expected value. If,
at any time during this process the DLCM detects an error the following screen is displayed:

ENCODER ERROR

PRESS ENTER

There could be internal damage to the encoder or gear train – possibly an obstruction or a broken
gear.

The {ENCODER ERROR / PRESS ENTER} screen is also displayed if the DLCM times out while

trying to adjust the Stroke Position and senses no detected motion.

Press [ENTER] and the following status screen is displayed

TURN MOTOR ON

TESTING ENCODER

Prior to turning the motor on, gently rotate the Manual Control Knob in both directions. If there
is a minor jam in the encoder gear train, this simple action could clear it.

Press [MOTOR] and the following screen is displayed.

PLEASE WAIT

TESTING ENCODER

If the encoder error has been cleared, the DLCM will continue with the {ZERO CALIBRATION}
procedure.

If the encoder error is still present, the following screen is displayed:

ENCODER ERROR

PRESS ENTER

At this time the operator should remove power from the DLCM, and contact Technical Services.

There is no way to bypass the Encoder Test in the {CALIBRATING ZERO} process.