Port Configuration

3-111

3

Field Attributes (CLI)

Basic Information:
Port type – Indicates the port type. (100BASE-FX, 1000BASE-T, or SFP)
MAC address – The physical layer address for this port. (To access this item on

the web, see “Setting the Switch’s IP Address” on page 3-16.)

Configuration:
Name – Interface label.
Port admin – Shows if the interface is enabled or disabled (i.e., up or down).
Speed-duplex – Shows the current speed and duplex mode. (Auto, or fixed choice)
Capabilities – Specifies the capabilities to be advertised for a port during

auto-negotiation. (To access this item on the web, see “Configuring Interface
Connections” on page 3-48.) The following capabilities are supported.
- 10half - Supports 10 Mbps half-duplex operation
- 10full - Supports 10 Mbps full-duplex operation
- 100half - Supports 100 Mbps half-duplex operation
- 100full - Supports 100 Mbps full-duplex operation
- 1000full - Supports 1000 Mbps full-duplex operation
- Sym - Transmits and receives pause frames for flow control
- FC - Supports flow control

Broadcast storm – Shows if broadcast storm control is enabled or disabled.
Broadcast storm limit – Shows the broadcast storm threshold. (240-1488100

packets per second)

Flow control – Shows if flow control is enabled or disabled.
LACP – Shows if LACP is enabled or disabled.
Port Security – Shows if port security is enabled or disabled.
Max MAC count – Shows the maximum number of MAC address that can be

learned by a port. (0 - 1024 addresses)

Port security action – Shows the response to take when a security violation is

detected. (shutdown, trap, trap-and-shutdown, or none)

Current Status:
Link Status – Indicates if the link is up or down.
Port Operation Status – Provides detailed information on port state.

(Displayed only when the link is up.)

Operation speed-duplex – Shows the current speed and duplex mode.
Flow control type – Indicates the type of flow control currently in use.

(IEEE 802.3x, Back-Pressure or none)