Equipment configuration settings for rate control, Speed input settings, Peed – Ag Leader Versa Users Manual User Manual
Page 86: Nput, Ettings
![background image](/manuals/401072/86/background.png)
72
Firmware Version 5.4
Equipment Configuration Settings for Rate Control
If you are using an operating configuration with Rate
Control, (such as for certain DirectCommand and
SeedCommand configurations) you must specify
Equipment Configuration Settings. At the
Configuration Setup screen, press the Configuration
Settings button. The Equipment Configuration
Settings screen appears.
These settings are directly related to that specific combination of Vehicle, Implement, and Controller.
• The configuration name can be changed by pressing
.
• The Rate Outside of Field selection determines product control channel behavior when the field
boundary is exited.
- Zero Product - Product application will turn off.
- Last Good - Product application will continue at the last value used by the control system.
- Rx Default - Product will be applied at the default rate setting.
• Rate Display Smoothing setting
Determines how the feedback from the control channel rate sensor will be displayed on the map screen.
When de-selected, the system will display raw feedback from the rate sensor. When checked, the system
will display target rate when the application rate is within 10% of the target rate setting.
• Controller Time Delay setting
Compensates for any latency in the control system when changing between different product flow rates
during variable rate application. The typical setting range for this is 0 - 1 seconds.
S
PEED
I
NPUT
S
ETTINGS
Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Speed Input button
Equipment Configuration Settings
Rate Outside of Field
Rate Display
Smoothing
0 sec
Controller
Time Delay
Zero
Configuration
Your Specific
Configuration
Speed
Input