beautypg.com

Troubleshooting serial control applications, Roubleshooting, Erial – Ag Leader Versa Users Manual User Manual

Page 259: Ontrol, Pplications

background image

245

A

PPLICATION

S

PREADER

2. Make sure the applicator is inside of the field boundary.

Problem: Conveyor turns off in the middle of the pass.

Solution: Check the display firmware and module firmware to see if they are running the

latest version.

Problem: Total Applied does not match Actual Weight Applied.

Solution:

1. Make sure the shaft speed pls/rev are set correctly in the controller settings.

2. Make sure the controlling product is set to the correct units.

Problem: Rate not responding.

Solution:

1. Make sure there is a ground speed registering on the display.

2. Make sure the shaft speed pls/rev are set correctly in the controller settings.

(You must make sure to account for sprocket ratios if chain driven).

3. Check the user-defined value found under the controller settings for Strip-Till.

4. The CFR number may need to be adjusted.

T

ROUBLESHOOTING

S

ERIAL

C

ONTROL

A

PPLICATIONS

Problem: Rate changes on the display, but not on the controlled console.

Solution:

1. Verify the current firmware is running on the display and Application Rate module.

2. Check the settings specific to your controlled console. (For more information, refer to the Quick

Reference Guide).

3. Check cabling and all connections.

4. Disconnect the serial connection and determine if the controller is functioning properly without

the display.

Problem: The display rate and serial-controlled rate do not match.

Solution:

1. Verify the current firmware is running on the display and Application Rate Module.

2. Check to make sure the nominal rate in the display matches the nominal rate in the serial-

controlled console.

Driven Teeth

X Rate Sensor Pulses = True Pulses

Drive Teeth