1. Run Separator
Start the separator and feeder house with the proper header attached. Run at full speed.
CAUTION: Do not harvest a crop during the Vibration Calibration process.
2. Press Start
With the combine separator running at full operating speed with the header engaged, press the Start button.
The display counts down 60 seconds.
3. Calibration Number Displayed
When the vibration calibration is complete, a message appears underneath the Start button stating
“Calibration Complete.” Next to this, the vibration calibration number is displayed. Press
to return
to the Calibration Tab. You may now turn off the separator
T
EMPERATURE
C
ALIBRATION
A Temperature Calibration only needs to be performed once per season. Changing this calibration will
affect harvested data collected after the calibration.
Press: Map button > Moisture button > Temperature tab
CAUTION: Only calibrate the temperature before harvesting begins.
1. Place Combine in Shady Spot
Leave the combine parked in a shaded area or a shed for a few hours. The temperature calibration should
not be performed if the sensor has been in direct sunlight or is sitting next to grain.
2. Take Air Temperature Reading
Take an accurate air temperature reading using a thermometer in the same shaded area.
3. Enter Outside Air Temperature.
Use
/
to enter the known outside air temperature. Make the proper adjustments until the
Calibrated Temperature shown at the top of this screen reflects the correct air temperature.
When finished, press
.
M
OISTURE
C
ALIBRATION
A moisture calibration only needs to be done once per crop, per season. Changing this calibration will
affect harvested data collected after the calibration.
Press: Map button > Moisture button > Temperature tab
Moisture
Temperature
Moisture
Moisture