HP ProLiant DL760 Server User Manual
Page 202
![background image](/manuals/397974/202/background.png)
Troubleshooting Information E-3
Compaq Confidential – Need to Know Required
Writer: Bryce Miller Project: Compaq ProLiant DL760 Servers User Guide Comments:
Part Number: 173744-001 File Name: o-appe Troubleshooting Information.doc Last Saved On: 1/25/01 3:06 PM
7. Check the Integrated Management Display (IMD) for the following
“normal power-up sequence” to verify that your system meets the
minimal hardware requirements and is powered up under normal
operation:
a. The front panel system LED turns from standby (blinking green) to
on (solid green).
b. The fans start up.
c. The IMD displays messages regarding the server name and LCD
firmware version.
d. The IMD displays messages regarding server initialization in the
following sequence:
G
System initialization
G
PCI auto-configuration
G
Video initialization. If a monitor is connected, it also displays the
Compaq initialization screen.
G
Processor initialization
G
Memory test
G
Memory initialization
G
Diskette drive
G
Option ROM
G
SCSI devices
8. The operating system loads to complete the boot process.
If this does not solve the problem, continue with the following section