Replacing Hot-Plug Fans
The ProLiant DL760 server ships with two hot-plug fans. Fan 1 is closest to
the rear of the server. Each fan has LED indicators that indicate the status of
the fan as follows:
■
No light—power is not applied to the fan
■
Green light
—power is applied to the fan and the fan is functional
■
Amber light
—the fan has failed
2
1
Figure 5-17. Hot-plug fan LED indicators
CAUTION: Never remove both hot-plug fans while the server is powered up.
Overheating and damage to hardware could result. If the appropriate Compaq
software drivers are installed, the operating system software will initiate a
power shutdown in the event of overheating.
NOTE: The hot-plug fan LED indicators are not part of the fan housing. Figure 5-17
shows the LED indicators as if the fan were installed in the server.