HP ProLiant DL760 Server User Manual
Page 145
![background image](/manuals/397974/145/background.png)
7-6 Compaq ProLiant DL760 Servers User Guide
Compaq Confidential – Need to Know Required
Writer: Bryce Miller Project: Compaq ProLiant DL760 Servers User Guide Comments:
Part Number: 173774-001 File Name: h-ch7 Server Power.doc Last Saved On: 1/18/01 6:14 PM
1
3
5
7
9
11
13
15
17
Shutdown
P8
P7
P6
P5
P4
P3
P2
P1
Memory
9 VRM
Host Mod
I/O Mod
Media Mod
SCSI Bd 1
SCSI Bd 2
Reset
2
4
6
8
10
12
14
16
Figure 7-3. System interconnect status LED indicators
Table 7-3
System Interconnect Status LED Indicators
Item
Component
Item
Component
Emergency
Shutdown
1
Memory board
Processor 8
Termination PPM
Processor 7
Processor and
Memory Module
Processor 6
I/O module
Processor 5
Media module
Processor 4
SCSI backplane 1
Processor 3
SCSI backplane 2
Processor 2
System Reset
2
Processor 1
Note 1: AC power to the system has been cut to avert imminent component damage and
data loss. Reasons for this could include: the failure of the terminator Processor Power
Module (PPM), a non-responsive fan controller, or the system has recorded a temperature
violation.
Note 2: A power supply has stopped providing adequate power as per system
specifications, the system has experienced a short, a PPM has failed, or a reboot has been
initiated via Automatic Server Recovery (ASR-2).