HP Traffic Director sa7220 User Manual
Page 112

C H A P T E R 4
HP Traffic Director Server Appliances User Guide
100
•
The CLI (SSH) Port field specifies the secure telnet port on
which the CLI runs. Valid ports are port 22 (the default) or any
unused port between 1024 and 65535.
•
The CLI (telnet) Port field allows you to specify the standard
(unencrypted) telnet port on which the CLI runs. Valid ports are
port 23 or any port between 1024 and 65535. The default is port
23.
•
The Telnet Sessions field allows you to specify the maximum
number of concurrent inbound remote CLI logon sessions
allowed. This value must be an integer between 1 and 8. The
default is 3.
•
Use the Timeout field to set or change the idle timeout period
before automatic logoff for CLI sessions. This feature is disabled
by setting the timeout value to "0." This timeout period is
expressed in seconds (0, or 30 to 65535). The default is 900
seconds (15 minutes).
•
Use the Prompt field to set or change the root level prompt. The
default prompt is an abbreviation of the product's name, for
example: "HP SA8220."
•
The Login Attempts field allows you to specify the maximum
allowable number of failed login attempts before closing the
connection. The valid range is from 1 to 30.
•
Use 'more' for screen paging. When this box is not checked, the
CLI outputs a continuous scrolling display. When the box is
checked, the CLI scrolls one page at time.
•
When more is selected, the Lines per screen field becomes
available. Use this field to specify the number of lines more
displays at a time.
1. Click Apply.