beautypg.com

Emu display groups – HP 3000 Enterprise Virtual Array User Manual

Page 76

background image

2.

Function select (top push-button)

3.

Display Group select (bottom push-button)

NOTE:

7-segment display limitations preclude displaying uppercase characters B, K, M, N, Q, R, S, T, V, W, X,

Y, or Z, or the lowercase characters a, e, f, g, j, k, l, m, p, q, s, t, v, w, x, y, or z. The lowercase characters

b, c, d, h, i, o, r, and u displays are similar to the actual characters.

Alphanumeric display description

The top-level, two-character alphanumeric display (En, Li, rG, Au, and Er), is the display group. The

function of the other displays is display-group dependent. The default display is the enclosure number,

a decimal number in the range 00 through 14. The push-buttons allow you to select the alphanumeric

display or to enter data.

The bottom push-button (see 3,

Figure 35

) enables you to sequentially move between groups and

to select a display group.
See

EMU display groups

for a description of these display groups.

The top push-button, (see 2,

Figure 35

) enables you to move between the levels within a display

group.

Display groups

When you press and release the bottom push-button, the alphanumeric display selects a different display

group.

EMU display groups

describes the display groups.

Table 19 EMU display groups

Display

Display Group

Description

En

Enclosure Number

The enclosure number is the default

display and is a decimal number

in the range 00 through 14. See

Using the Enclosure Number

Feature

for detailed information.

Li

Bay

1 Loop ID

This display group has a single

sublevel display that defines the

enclosure bay 1 loop ID. Valid

loop IDs are in the range 00

through 7F.

rG

Reporting Group

This display group has two, 2-digit

displays that define the reporting

group number in the range 0000

through 4095.

Au

Audible Alarm

This display group provides

control over the audible alarm or

horn. The sublevel displays are

audible alarm enabled (on) or

audible alarm disabled (oF). See

Enclosure and Element Conditions

for detailed information.

Fr

Firmware Revision

This display group defines the

EMU code firmware version.

Er

Error Condition

This display group reads Er when

there is an error condition. See

Enclosure and Element Conditions

for detailed information.

76