beautypg.com

Environmental specifications, Rack, Physical specifications – HP 3000 Enterprise Virtual Array User Manual

Page 130: Ac input current and wattage, Controller power supply output specifications

background image

Table 41 AC input current and wattage

Nominal

Maximum

Input voltage

Amps

Watts

Amps

Watts

60-Hz Input
100 VAC–JBOD

4.35

436

6.41

641

208 VAC–North America

2.03

419

2.94

609

50-Hz Input
120 VAC–JBOD

3.59

419

5.27

633

220 VAC–North America

1.92

418

2.78

608

230 VAC–North America

1.92

418

2.78

608

240 VAC–Europe

1.76

416

2.55

607

Table 42 Controller power supply output specifications

Voltage Specification

Minimum

Nominal

Maximum

+3.3 VDC
Output VoltageSteady state current

Power

3.23 VDC

3.30 VDC

3.36 VDC 18 A

1

59.4W

+5.0 VDC
Output Voltage Steady state current

Power

4.90 VDC

5.00 VDC

5.10 VDC 4 A 20.0W

+12.0 VDC
Output Voltage Steady state current

Power

11.4 VDC

12.0 VDC

12.6 VDC 2 A 4.0W

Total Current Total Power

24 A 65.4W

1

1

+3.3 VDC steady state current requires a minimum 5.0-V load of 1 A.

Environmental specifications

There are no controller environmental specifications. See the

Rack

environmental specifications for this

information in the next section.

Rack

Physical specifications

WARNING!

The weight of the drive enclosure with the elements installed always requires at least two individuals to

move. HP recommends using a fork lift or a hand truck to move an enclosure in the shipping container.

Table 43

through

Table 48

define the dimensions and weights of the 9000-Series and 10000-Series

Enterprise Virtual Array racks.

130

Regulatory notices and specifications