beautypg.com

Entering data using the ocp, Setting up a controller pair using the ocp, Sample node wwn label – HP 3000 Enterprise Virtual Array User Manual

Page 37

background image

Move the rack.

Stabilize the rack.

Inspect the storage system.

Install the controller cache batteries.

Apply power.

Attach the controllers to the fabric.

Entering data using the OCP

Two pieces of data critical to initial setup must be entered into the OCP:

WWN—Mandatory to complete setup.

Storage system password—Optional. A password is a security interlock that allows only specific

instances of Command View EVA to access the storage system.

Setting up a controller pair using the OCP

Fibre Channel protocol requires that each controller pair has a unique Node WWN. This 16-character

alphanumeric name identifies the controller pair on the storage system. The Enterprise Virtual Array

World Wide Name Label identifies the WWN for each storage system. The Node WWN labels, similar

to the one shown in

Figure 11

, identify the storage system WWN and checksum. During the installation of

the storage system, two WWN labels are attached to the rack on both sides of the controller enclosures.

CXO7545A

Figure 11 Sample node WWN label

NOTE:

The controller pair WWN is unique to a controller pair and cannot be used for any other controller pair

or device anywhere on the network.

Figure 12

shows the location of the WWN label on a controller pair.

This is the only WWN applicable to any controller installed in a specific physical location, even a

replacement controller.
Once a WWN is assigned to a controller, you cannot change the WWN while the controller is part

of the same storage system.

Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)

37