19 unrecoverable condition—emu esi driver failure, Transceiver conditions, Transceiver element numbering – HP 3000 Enterprise Virtual Array User Manual

Page 148: Figure 63

background image

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error does not recur within the first minute.

4.

If the error does recur, contact your HP authorized service representative. The EMU is inoperative

and must be replaced as soon as possible.

0.7.01.19 UNRECOVERABLE condition—EMU ESI driver failure

The EMU has detected an internal hardware problem. This condition report remains active until the

problem is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error does not recur within the first minute.

4.

If the error does recur, contact your HP authorized service representative. The EMU is inoperative

and must be replaced as soon as possible.

Transceiver conditions

The format of a transceiver condition report is 0.F.en.ec, where:

0.F. is the transceiver element type number

en. is the two-character transceiver element number (see

Figure 63

)

ec is the error code

CXO7954A

3

1

4

2

Figure 63 Transceiver element numbering
1.

Transceiver 01

2.

Transceiver 02

3.

Transceiver 03

4.

Transceiver 04

0.F.en.01 CRITICAL Condition—Transceiver Incompatibility

The transceivers on this link are not the same type or they are incompatible with the I/O module. This

error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure

dual-loop capability. This error remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

148

EMU generated condition reports