19 unrecoverable condition—emu esi driver failure, Transceiver conditions, Transceiver element numbering – HP 3000 Enterprise Virtual Array User Manual
Page 148: Figure 63
![background image](/manuals/397449/148/background.png)
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is inoperative
and must be replaced as soon as possible.
0.7.01.19 UNRECOVERABLE condition—EMU ESI driver failure
The EMU has detected an internal hardware problem. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is inoperative
and must be replaced as soon as possible.
Transceiver conditions
The format of a transceiver condition report is 0.F.en.ec, where:
•
0.F. is the transceiver element type number
•
en. is the two-character transceiver element number (see
•
ec is the error code
CXO7954A
3
1
4
2
Figure 63 Transceiver element numbering
1.
Transceiver 01
2.
Transceiver 02
3.
Transceiver 03
4.
Transceiver 04
0.F.en.01 CRITICAL Condition—Transceiver Incompatibility
The transceivers on this link are not the same type or they are incompatible with the I/O module. This
error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure
dual-loop capability. This error remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.