Table 18 EMU LED displays

EMU LED green

Power LED

green

Fault LED amber

Status and recommended actions

Flashing

Flashing

Flashing

The EMU locate function is active. This

display has precedence over all others.

Fault conditions cannot be displayed when

the locate function is active.

Flashing

On

Off

The EMU is operational. The enclosure

power (both +5 V DC and +12 V DC)

is present and correct. There are NO

enclosure faults.

Flashing

On

On

The EMU is operational. There is an

enclosure fault. Check the alphanumeric

display error code for detailed information

about the problem.

Flashing

Off

Off

The EMU is operational. This display may

be present when power is initially applied

to the enclosure. Note: When the +5 VDC

is incorrect, all the LEDs are Off.

On

On

Off

There is an EMU fault There is no enclosure

fault.

Off

On

Off

There is an EMU fault There is no enclosure

fault.

Off

Off

Off

There is an enclosure fault. Either +5 VDC

is incorrect, or both +5 VDC and +12

VDC are incorrect. Other error conditions

may exist.

Using the alphanumeric display

The two-character alphanumeric display is located at the top of the EMU (see 1,

Figure 35

). This

7-segment display provides information about multiple enclosure functions. The push-buttons control

the data displayed or entered.

CXO7373A

2

3

1

Figure 35 Alphanumeric display and controls
1.

Alphanumeric display

Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)