beautypg.com

Power supply conditions – HP 3000 Enterprise Virtual Array User Manual

Page 138

background image

This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Remove and replace the drive in the enclosure.

3.

Observe the drive status LEDs to ensure the drive is operational.

4.

Observe the EMU to ensure the error is corrected.

5.

If removing and replacing the drive did not correct the problem, replace the drive.

6.

Observe the drive status LEDs to ensure the drive is operational.

7.

Observe the EMU to ensure the error is corrected.

8.

If unable to correct the problem, contact your authorized service representative.

0.1.en.05 CRITICAL condition—Loop B drive link rate incorrect

The drive is capable of operating at the loop link rate but is running at a different rate. For example, the

drive is operating at 1Gbps, and the loop is operating at 2Gbps. Only when the drive is operating at the

Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Remove and replace the drive in the enclosure.

3.

Observe the drive status LEDs to ensure the drive is operational.

4.

Observe the EMU to ensure the error is corrected.

5.

If removing and replacing the drive did not correct the problem, replace the drive.

6.

Observe the drive status LEDs to ensure the drive is operational.

7.

Observe the EMU to ensure the error is corrected.

8.

If unable to correct the problem, contact your authorized service representative.

Power supply conditions

The format of a power supply condition report is 0.2.en.ec, where:

0.2. is the power supply element type number

en. is the two-character power supply element number

ec is the error code

Figure 60

shows the location of power supply 1 and power supply 2.

138

EMU generated condition reports