Power supply conditions – HP 3000 Enterprise Virtual Array User Manual
Page 138
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status LEDs to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
5.
If removing and replacing the drive did not correct the problem, replace the drive.
6.
Observe the drive status LEDs to ensure the drive is operational.
7.
Observe the EMU to ensure the error is corrected.
8.
If unable to correct the problem, contact your authorized service representative.
0.1.en.05 CRITICAL condition—Loop B drive link rate incorrect
The drive is capable of operating at the loop link rate but is running at a different rate. For example, the
drive is operating at 1Gbps, and the loop is operating at 2Gbps. Only when the drive is operating at the
Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status LEDs to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
5.
If removing and replacing the drive did not correct the problem, replace the drive.
6.
Observe the drive status LEDs to ensure the drive is operational.
7.
Observe the EMU to ensure the error is corrected.
8.
If unable to correct the problem, contact your authorized service representative.
Power supply conditions
The format of a power supply condition report is 0.2.en.ec, where:
•
0.2. is the power supply element type number
•
en. is the two-character power supply element number
•
ec is the error code
shows the location of power supply 1 and power supply 2.
138
EMU generated condition reports