beautypg.com

HP 3000 Enterprise Virtual Array User Manual

Page 43

background image

4.

Wait three minutes and then verify that all disk drives are ready. The drive ready indicator and

the drive online indicator should be on (green).

5.

Power on the upper HSV controller. It will assume the roll of master controller.

6.

Wait 10 seconds and then power on the lower controller. It will assume the roll of slave controller.

7.

Verify that the (Operator Control Panel) OCP display on each controller displays the storage system

name and the EVA WWID.

8.

Launch Command View EVA and verify connection to the storage system. If the storage system is

not visible, click the HSV Storage Network icon in the Navigation pane to discover the recently

restarted storage system.

NOTE:

If the storage system is still not seen, it may be necessary to reboot the SMA to re-establish

the communication link.

9.

Check the array status using Command View EVA to ensure everything is operating properly. If any

status indicator is not normal, check the log files or contact your HP service provider for assistance.

Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)

43