beautypg.com

Fibre channel drive enclosure, Fibre channel loop switches, Fc drive enclosure – HP 3000 Enterprise Virtual Array User Manual

Page 24

background image

Each hardware component is identified in the following sections and is described in detail in

Storage

System Hardware Components

.

Fibre Channel drive enclosure

Each FC drive enclosure includes the following features:

3U

drive enclosure

Dual-redundant, active-to-active, 2-Gbps FC loops

Fourteen 1-inch FC disks per enclosure

Environmental Monitoring Unit (EMU)

Dual 2-Gbps FC I/O modules—A and B loops
• Enhanced fault detection
• Single Gigabit Interface Converter

Dual 500-W redundant hot-plug power supplies and

blowers

For ease of reference, the disk drives are referred to by their physical location, the drive bay number.

Figure 5

shows the front view of the FC drive enclosure and the physical location of each drive bay.

CXO7942A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Figure 5 FC drive enclosure

1–14 drive bays
15 enclosure status indicators

Fibre Channel loop switches

The EVA5000 uses four FC loop switches to connect all of the drive enclosures to the controller pair

via FC cables. Each switch acts as a central point of interconnection and establishes a fault-tolerant

physical loop topology.
The major features of the FC loop switches are:

2.125 Gbps operating speed

Twelve ports

Half-width, 1U size

System and port status LED indicators

Universal power supply that operates between 100 to 250 VAC and 50 to 60 Hz

Small Form-factor Pluggable (SFP) transceivers

Figure 6

shows the bezel and front view of the FC loop switch.

24

System description