En.01 noncritical condition—high voltage, En.02 critical condition—high voltage, En.03 noncritical condition—low voltage – HP 3000 Enterprise Virtual Array User Manual
Page 150: En.04 critical condition—low voltage, En.01 noncritical condition—high current, En.02 critical condition—high current, Voltage and current sensor locations, Table 54
Table 54 Voltage and Current Sensor Locations
Sensor
Sensor Element Location
01.
Power Supply 1 +5 VDC
02.
Power Supply 1 +12 VDC
03.
Power Supply 2 +5 VDC
04.
Power Supply 2 +1 VDC
Use HP Command View EVA to view the voltage and current error thresholds for both +5 VDC and +12
VDC power supplies.
1.2.en.01 NONCRITICAL Condition—High Voltage
This condition report indicates that an element voltage is approaching, but has not reached, the high
voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL
condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
1.2.en.02 CRITICAL Condition—High Voltage
This condition report indicates that an element voltage has reached the high voltage CRITICAL threshold.
This report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
1.2.en.03 NONCRITICAL Condition—Low Voltage
This condition report indicates that an element voltage is approaching, but has not reached, the low
voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL
condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
1.2.en.04 CRITICAL Condition—Low Voltage
This condition report indicates that an element voltage has reached the low voltage CRITICAL threshold.
This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
1.3.en.01 NONCRITICAL Condition—High Current
This condition report indicates that an element current is approaching, but has not reached, the high
current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL
condition. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
1.3.en.02 CRITICAL Condition—High Current
This condition report indicates that an element current has reached the high current CRITICAL threshold.
This condition report remains active until the problem is corrected.
150
EMU generated condition reports