En.03 unrecoverable condition—blower failure, En.04 unrecoverable condition—blower internal, En.05 noncritical condition—blower missing – HP 3000 Enterprise Virtual Array User Manual
Page 141: En.06 unrecoverable condition—no blowers installed, Temperature conditions
![background image](/manuals/397449/141/background.png)
To correct this problem, record all six characters of the condition report, then contact your authorized
service representative.
0.3.en.03 UNRECOVERABLE condition—Blower failure
A
blower
has stopped. The operational blower now operates at high speed and is a single point of
failure. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your authorized
service representative.
0.3.en.04 UNRECOVERABLE condition—Blower internal
A power supply reported an internal
blower
error that could affect enclosure cooling and cause an
element to fail. HP recommends correcting the problem before the blower fails. This condition report
remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
0.3.en.05 NONCRITICAL condition—Blower missing
A
blower
has been removed or is improperly installed. Even though the blower flaps close to maintain
the proper air flow, the reduced cooling capability can cause overheating, causing an element to fail.
This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
0.3.en.06 UNRECOVERABLE condition—No blowers installed
NOTE:
IMPORTANT
When this condition exists there will be two error messages.
The first message will be 0.3.en.05 and will identify the first
blower
.
The second message will be 0.3.en.06 and will identify the second
blower
.
The EMU cannot detect any installed
blowers
. Shutdown is imminent! The EMU will shut down the
enclosure in seven minutes unless you correct the problem. This condition report remains active until you
correct the problem or the EMU shuts down the power supplies, whichever occurs first.
Complete the following procedure to correct this problem.
1.
Record all six characters of the condition report.
2.
Use the controller shutdown procedure to shut down the controllers.
3.
Contact your authorized service representative.
CAUTION:
An automatic shutdown and possible data corruption may result if the
blower
is removed before
a replacement is available.
Temperature conditions
The format of a temperature condition report is 0.4.en.ec, where:
•
0.4. is temperature sensor element type
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
141