Drive enclosure emu, Power supply/blower status indicators – HP 3000 Enterprise Virtual Array User Manual

Page 70

background image

NOTE:

The

blower

units are field-replaceable units. The units can be replaced, individually, while the system is

running. The units are also interchangeable. The failure of a power supply +12.5 VDC circuit disables

the associated

blower

.

Power supply and blower status reporting

The green status LED on the

blower

displays the status of both the power supply and the blower. See

Table 15

for definitions of the LED displays.

Table 15 Power supply/blower status indicators

Blower status LED

Description

On

Both the power supply and the blower are operational.

Flashing

The power supply or the blower locate function is active.

Off

The power supply or the blower is non–operational. When there is a blower problem,

the other blower runs at a higher speed. Recommended corrective actions:

Check blower for proper operation. Replace if defective.

Check power supplies for proper operation. Replace if defective.

Drive enclosure EMU

The EMU provides increased protection against catastrophic failures. The EMU detects conditions such

as failed power supplies, failed

blowers

, elevated temperatures, and external air sense faults and

communicates these conditions to the storage system controllers.

Figure 31

shows the drive enclosure EMU as a standalone unit.

CXO6697A

Figure 31 Drive enclosure EMU

The EMU for Fibre Channel-Arbitrated Loop (FC–AL) drive enclosures is fully compliant with SCSI-3

Enclosure Services (SES), and mounts in the left rear

bay

of a drive enclosure (see 1,

Figure 32

).

70

Storage system hardware components