Drive enclosure emu, Power supply/blower status indicators – HP 3000 Enterprise Virtual Array User Manual
Page 70

NOTE:
The
blower
units are field-replaceable units. The units can be replaced, individually, while the system is
running. The units are also interchangeable. The failure of a power supply +12.5 VDC circuit disables
the associated
blower
.
Power supply and blower status reporting
The green status LED on the
blower
displays the status of both the power supply and the blower. See
for definitions of the LED displays.
Table 15 Power supply/blower status indicators
Blower status LED
Description
On
Both the power supply and the blower are operational.
Flashing
The power supply or the blower locate function is active.
Off
The power supply or the blower is non–operational. When there is a blower problem,
the other blower runs at a higher speed. Recommended corrective actions:
•
Check blower for proper operation. Replace if defective.
•
Check power supplies for proper operation. Replace if defective.
Drive enclosure EMU
The EMU provides increased protection against catastrophic failures. The EMU detects conditions such
as failed power supplies, failed
blowers
, elevated temperatures, and external air sense faults and
communicates these conditions to the storage system controllers.
shows the drive enclosure EMU as a standalone unit.
CXO6697A
Figure 31 Drive enclosure EMU
The EMU for Fibre Channel-Arbitrated Loop (FC–AL) drive enclosures is fully compliant with SCSI-3
Enclosure Services (SES), and mounts in the left rear
bay
of a drive enclosure (see 1,
70
Storage system hardware components