beautypg.com

Viewing drive cage alerts details – HP 3PAR Operating System Software User Manual

Page 335

background image

The following information is provided for non-SAS drive cages:

Description

Column

The drive cage to which the power supply belongs.

Cage

Numeric ID of the power supply.

ID

Status of the physical disk. See

“System and Component Status Icons” (page 508)

.

State

Model name of the power supply.

Model

Indicates the presence of AC power to the power supply.

AC State

Power supply fan operational status.

Fan State

Speed of the power supply fan.

Fan Speed

The following information is provided for DCS1 and DCS2 drive cages:

Description

Column

The drive cage to which the power supply belongs.

Cage

Numeric ID of the power supply.

ID

Status of the physical disk. See

“System and Component Status Icons” (page 508)

.

State

Model name of the power supply.

Model

Indicates the presence of AC power to the power supply.

AC State

Indicates the presence of DC power to the power supply.

DC State

Power supply fan 0 operational status.

Fan 0 State

Speed of the power supply fan 0.

Fan 0 Speed

Power supply fan 1 operational status.

Fan 1 State

Speed of the power supply fan 1.

Fan 1 Speed

Viewing Drive Cage Alerts Details

The Alerts detail tab provides the following information:

Description

Column

The severity of the alert. See

“Alert Severity Indicators” (page 507)

.

Severity

The alert ID.

ID

The alert state.

State

Viewing Drive Cage Alerts Details 335