beautypg.com

Viewing drive cage connectivity – HP 3PAR Operating System Software User Manual

Page 323

background image

Description

Column

The port speed in Gbps.

Speed

The number of disks in the drive cage. The bottom of the Disks column displays
a total disk count.

Disks

The total Fast Class capacity in GiB. The bottom of the FC Total column displays
total FC capacity for all cages.

FC Total

The percentage of used Fast Class capacity. The bottom of the FC Allocated
Percentage column displays the total used percentage.

FC Allocated Percentage

The total NL capacity, in GiB. The bottom of the NL Total column displays total
FC capacity for all cages.

NL Total

The percentage of used NL capacity.

NL Allocated Percentage

The total SSD capacity in GiB. The bottom of the SSD Total column displays total
SSD capacity for all cages.

SSD Total

The percentage of used SSD capacity. The bottom of the SSD Allocated Percentage
column displays the total used percentage.

SSD Allocated Percentage

NOTE:

The device types displayed in the summary are dependent on the devices installed in your system. For

example, if you have Near Line and disk drives installed, the summary display includes the following columns: NL
(Near Line) Total, NL Allocated Percentage.

The Summary tab can be further filtered to view drive cage connectivity and drive cage capacity.

Viewing Drive Cage Connectivity

To view drive cage connectivity information, select Connectivity from the filter list.

The following information is provided:

Description

Column

The drive cage ID.

ID

The drive cage name.

Name

The drive cage state. See

“System and Component Status Icons” (page 508)

.

State

Distance the drive cage is from the controller node port. (0 = directly connected to
system ports, 1= there is one device between the node and this drive cage, and so on).

Position A

Version of firmware running on the controller for the A loop.

Revision A

Distance the drive cage is from the controller node port. (0 = directly connected to
system ports, 1= there is one device between the node and this drive cage, and so on).

Position B

Version of firmware running on the controller for the B loop.

Revision B

Controller node initiator port connected to drive cage port A0.

A0 Port

Controller node initiator port connected to drive cage port A1.

A1 Port

Viewing Drive Cages 323