2.

Define a target on the backup system (for example, System2).

For RCIP:

# creatercopytarget IP :

:

- Name of the target system (for example, System1)

IP

- Defines link as an IP link

- Location on the current system (System2) that contains the IP connections

to the target system, expressed as node:slot:port

- Link IP address for the corresponding port on the target system

(for example, 172.16.1.11 or 172.16.2.11)

For RCFC:

# creatercopytarget FC

- Name of the target system (for example, System1)

FC

- Defines link as an FC link

- WWN of the node on the target system

- Location on the current system (System2) of the FC adaptor port,

expressed as node:slot:port, and the WWN of the corresponding node on the target
system

Checking the Links between Systems

1.

To check the links between the primary and backup systems, issue the showrcopy command
on the backup system (for example, System2):

# showrcopy

It might take several minutes for the links to come up between the two storage systems.

NOTE:

For complete details on the showrcopy command, including valid synchronization,

link, and group states, see

“The Remote Copy Commands” (page 224)

.

2.

Verify that:

The Target Information area shows a Status of ready.

The Link Information area shows a Status of Up for all the links.

For example, showrcopy output on System2 looks like:

Remote Copy System Information

Status: Started, Normal

Target Information

Name ID Type Status Options Policy

System1 112 IP ready mirror_config

Link Information

70

Setting Up a Unidirectional Configuration

This manual is related to the following products: