beautypg.com

Startrcopygroup, Name, Syntax – HP 3PAR Operating System Software User Manual

Page 273: Authority, Options, Specifiers, Restrictions, Examples

background image

startrcopygroup

NAME

startrcopygroup

-- The startrcopygroup command turns on Remote Copy for the specified

Remote Copy volume group.

SYNTAX

startrcopygroup [options ] |...

AUTHORITY

Super, Edit
Any role granted the rcopygroup_start right.

OPTIONS

-wait

Specifies that the command blocks until the initial synchronization is complete. The system
generates an event when the synchronization is complete.

-nosync

Prevents the initial synchronization and sets the volumes to a synchronized state.

-t

Indicates that only the group on the specified target is started. If this option is not used, by
default, the startrcopygroup command will affect all of a group’s targets.

-pat

Specifies that the patterns specified are treated as glob-style patterns and that all Remote Copy
groups matching the specified pattern will be started. This option must be used if the pattern
specifier is used.

SPECIFIERS

The name of the Remote Copy volume group. Can be obtained using the showrcopy command.

Specifies a glob-style pattern. This specifier can be repeated to start multiple groups. For more
information, issue: clihelp sub,globpat

RESTRICTIONS

This command requires the HP 3PAR Remote Copy Software license. Contact your local service
provider for further information.

EXAMPLES

The following example starts Remote Copy for Group1:

# startrcopygroup Group1

NOTES

If a group’s target has the mirror_config policy set and the group is a primary group,
then this command will be mirrored to that target and the corresponding secondary group
will be started. If the policy is set and the group is a secondary, then this command will fail.

If the mirror_config policy is not set, then the corresponding secondary group must already
be started or this command will fail.

Synchronous groups are automatically synchronized when started. Asynchronous periodic
volume groups are synchronized only on the first time they are started. When volumes are

273