Fc-connection – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 39

Command line 39
Item
Description
Syntax
show fabric [
Parameter
Name (optional)
Name of an existing fabric. Use “*” to display a detailed output of all fabrics in the VC
domain. If not specified, a summary output of all fabrics appears.
Examples
->show fabric
Displays a summary of all FC SAN fabrics
->show fabric *
Displays detailed information for all FC SAN fabrics
->show fabric SAN_5
Displays detailed information for a specific FC SAN fabric
fc-connection
Manage Fibre Channel SAN connections.
Supported actions: add, help, remove, set, show
Item
Description
add fc-connection
Add a new FC SAN connection to an existing server profile.
For more information, see "General requirements for adding FC or FCoE
)."
Syntax
add fc-connection
[Speed=
[AddressType=
[PortWWN=
Parameter
ProfileName (required) The name of an existing profile to which the new connection is added.
Properties
Fabric (optional)
The name of an existing fabric to associate with the connection. If the fabric
name is not specified, the connection is marked as “Unassigned” and
associated with a specific bay.
Speed (optional)
The port speed of the connection port. Values include "Auto", "1Gb", "2Gb",
"4Gb", "8Gb", and "Disabled". If not specified, the default port speed is set to
"Auto".
Speed restrictions:
For the HP VC 4Gb FC Module, supported speed values include
"Auto","1Gb","2Gb", "4Gb", and "Disabled". If the value is set to 8Gb, the
speed is auto-negotiated by VC.
AddressType (optional) The source of WWN address assignments used during the creation of the new
connection. If not specified, it defaults to the domain default. If "User-Defined" is
specified, then both a Port WWN and Node WWN must also be specified.
Values include "Factory-Default" and "User-Defined".
PortWWN (required if
AddressType is
User-Defined)
The user-defined Port WWN address to use for the connection. This property is
required if the AddressType specified is "User-Defined". The PortWWN must be
an unused WWN address.
NodeWWN (required if
AddressType is
User-Defined)
The user-defined Node WWN address to use for the connection. This property
is required if the AddressType specified is "User-Defined". The NodeWWN
must be an unused WWN address.
Examples
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem