HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 98

Command line 98
Item
Description
remove
server-port-map
Remove a server port network mapping.
Syntax
remove server-port-map
Parameters
ConnectionID
(required)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
to remove all server-port-map configurations from the domain.
Network (optional) The name of an Ethernet network on which the mapping exists
Examples
->remove server-port-map MyProfile:1 RedNetwork
Removes a server port network mapping
->remove server-port-map MyProfile:1 *
Removes all server port network mappings from a profile
->remove server-port-map *
Removes all server port mappings in the domain
Item
Description
set server-port-map Modify an existing server port network mapping. This command cannot be used if
the network is associated with a shared uplink set.
Syntax
set server-port-map
[VLanID=
Parameters
ConnectionID
(required)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
Network (required) The name of a valid Ethernet network on which the mapping exists
Properties
VLanID (optional)
The new VLAN ID to be used for server port network mapping. Valid values include
1 to 4094.
Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in
an Ethernet network connection can handle untagged packets. The default value is
"false". If a shared uplink set is used, the untagged network is the same as the native
network, if present, but any network can also be configured to handle untagged
packets. When changing a network untagged option from "true" to "false", you
must specify a VLanID if the global option SharedServerVLanId is set to "false".
Examples
->set server-port-map MyProfile:1 Network1 VLanId=100
Modifies the VLAN ID of an existing server port network mapping
->set server-port-map MyProfile:1 Network1 Untagged=true
Modifies the existing server port network mapping to handle untagged packets
Item
Description
show server-port-map Display a server port network mapping.
Syntax
show server-port-map [
Parameter
ConnectionID
(optional)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
Examples
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem