Uplinkset – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 124
Command line 124
Item
Description
PortID (optional) The ID of an uplink port. The PortID format is
uplink ports.
FilterBy
(optional)
Filters the output of the show command by the specified attribute. The option is
specified in the format
belonging to enclosure enc0, specify ID=enc0. To display all ports using an RJ-45
connector type, specify Type=RJ45. You can specify more than one filter option in a
single command, for example, show uplinkport ID=enc0 Type=RJ45.
Examples
->show uplinkport
Displays all uplink ports
->show uplinkport enc0:5:6
Displays details of uplink port 6 in bay 5 of the local enclosure
->show uplinkport *
Displays all uplink ports in the enclosure (detailed view)
->show uplinkport ID=enc0:1
Displays all the uplink ports for bay 1 of the local enclosure
->show uplinkport status=Linked
Displays all the uplink ports that are linked
->show uplinkport ID=enc0:1 type=RJ45
Displays all the uplink ports for bay 1 of the local enclosure with connector type RJ-45
uplinkset
Manage shared uplink sets.
Supported actions: add, copy, help, remove, set, show
Item
Description
add uplinkset
Create a new shared uplink set.
Syntax
add uplinkset
[ConnectionMode=
[LacpTimer=
Parameter
UplinkSetName
(required)
The unique name of the new shared uplink set to create
Properties
ConnectionMode
(optional)
Specifies the connection type that is formed when multiple ports are added to the
shared uplink set. Valid values include "Auto" and "Failover". The default value is
"Auto".
LacpTimer (optional) Specifies the domain default LACP timer. Valid values are "Domain-Default",
"Short", and "Long". This property can be specified only if the ConnectionMode is
"Auto".
Examples
->add uplinkset MyNewUplinkSet
Creates a new shared uplink set and adds it to the domain
->add uplinkset MyNewUplinkSet ConnectionMode=Failover
Creates a new shared uplink set and sets the connection mode to Failover
->add uplinkset MyNewUplinkSet ConnectionMode=Auto
LacpTimer=Domain-Default
Creates a new shared uplink set using the domain default LACP timer
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem