Profile – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 82

Command line 82
Item
Description
show port-protect
Display the loop protection and pause flood protection.
Syntax
show port-protect
Example
->show port-protect
Displays the loop protection and pause flood protection
profile
Manage server profiles.
NOTE:
For information on nPartitions and assigning a VC profile to an nPar, see the HP Virtual
Connect for c-Class BladeSystem User Guide on the Installing tab of the HP BladeSystem
Technical Resources websit
Supported actions: add, assign, copy, help, load, remove, save, set, show, unassign
Item
Description
add profile
Create a new server profile. After the profile is created, configure the profile using
the "set" subcommand, and additional network, fabric, and FCoE connections
added. The server profile can be assigned to a device bay using the "assign"
subcommand.
Profiles are created without FCoE connections if the QoS type is set to
"CustomNoFcoe". For more information about setting the QoS type, see "qos (on
)."
Syntax
add profile
[-NoDefaultFcConn] [-NoDefaultFcoeConn] [Nag=
[HideUnusedFlexNICs=
[SNType=
[SerialNumber=
Parameter
ProfileName
The unique name of the new server profile to create
Options
NoDefaultEnetConn
Do not add default Ethernet network connections when creating the server profile.
NoDefaultFcConn
Do not add default FC SAN connections when creating the server profile.
NoDefaultFcoeConn
Do not add default FCoE SAN connections when creating the server profile.
Properties
Nag (optional)
Network access group for the profile. The default is the domain default network
access group.
HideUnusedFlexNICs
(optional)
When set to "false," all physical functions of the FlexNICs are enumerated in the
operating system as network interfaces. This includes FlexNICs not mapped to
profile connections. Enumerating unmapped network interfaces might consume
shared resources, even though the interfaces are unused. The default is "true."
SNType (optional)
The source of the serial number assignment used during the profile creation. If not
specified, the serial number is assigned according to the VC default domain
settings. Values include "Factory-Default" and "User-Defined".
SerialNumber
(required if the
SNType is
"User-Defined")
A custom user-defined serial number associated with the server profile. When the
profile is assigned to a device bay containing a server, the server inherits the virtual
serial number. The user-defined serial number must start with the pattern VCX01.
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem