HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 72

Command line 72
Item
Description
NamePrefix (optional)
The string to prefix before the VLAN ID when naming the new networks. If
omitted, no string is used to prefix the VLAN ID.
NameSuffix (optional)
The string to add after the VLAN ID when naming the new networks. If
omitted, no string is added after the VLAN ID.
State (optional)
Enables or disables the networks. Valid values are "Enabled" and
"Disabled". The default value is "Enabled".
PrefSpeedType (optional)
The default connection speed for any Ethernet connection attached to
these networks. Valid values include "Auto" and "Custom". "Custom"
enables you to configure the preferred speed. The default value is "Auto".
PrefSpeed (required if
PrefSpeedType is "Custom")
The connection speed for any Ethernet connection attached to these
networks. Valid values range from 100Mb to 10Gb in 100Mb
increments.
MaxSpeedType (Optional)
The maximum connection speed for any Ethernet connection attached to
these networks. Valid values include "Unrestricted" and "Custom".
"Custom" enables you to configure the preferred speed. The default value
is "Unrestricted".
MaxSpeed (required if
MaxSpeedType is "Custom")
The maximum connection speed for any Ethernet connection attached to
these networks. Valid values range from 100Mb to 10Gb in 100Mb
increments.
Nags (optional)
The network access groups to which the networks belong, separated by
commas. Do not use spaces unless they are enclosed in quotation marks.
If no network access groups are specified, the domain default network
access group (Default) is used.
SmartLink (optional)
Enables or disables the SmartLink capability for the networks. Valid values
include "Enabled" and "Disabled".
Labels (optional)
Labels assigned to these networks. Labels are used in the GUI to help with
management of large numbers of networks. Labels can be assigned in the
CLI, but are only used in the GUI. A maximum of 16 labels can be
assigned.
Color (optional)
Color assigned to these networks. Color is used in the GUI to help with
management of large numbers of networks. A color can be assigned in
the CLI, but is only used in the GUI. Allowed colors are red, green, blue,
purple, or orange.
Examples
->add network-range UplinkSet=Alpha
NamePrefix=Network NameSuffix=_A VLANIDs=1-100
Creates 100 networks in an existing uplink set
->add network-range UplinkSet=Alpha
NamePrefix=Network NameSuffix=_A
VLANIDs=101-110,115-119,130,4094,700-703
Creates non-contiguous networks in an existing uplink set
Item
Description
remove network-range
Remove multiple networks from a shared uplink set.
Syntax
remove network-range [-quiet]
UplinkSet=
Options
quiet
Suppresses user confirmation prompts during network range removal. This
option is used mainly in automated scripting scenarios.
Properties
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem