HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 123

Command line 123
Item
Description
->remove uplinkport * Network=BlueNetwork
Removes all uplink ports from a network named BlueNetwork
->remove uplinkport enc0:2:3 UplinkSet=SharedUplinkSet1
Removes a specific uplink port (Bay 2, Port 3) from a shared uplink set
-> remove uplinkport 1:X1 UplinkSet=MyUplinkSet
Removes a specific uplink port (Bay 1, Port 1) from a shared uplink set that contains an
FCoE network (affects all modules within a bay group)
Item
Description
set uplinkport
Modify an uplink port that exists as a member of a network or shared uplink port set.
Syntax
set uplinkport
UplinkSet= 10Gb|Disabled>] [Role= Parameter PortID (required) The ID of the port to modify. The specified port must already be added to a network or shared uplink set. The port name for a network or an uplinkset that contains and FCoE network is in the format If the uplinkset contains an FCoE network, then the port is configured for all enclosures. Properties Network (required) The name of the network to which the port belongs if the shared uplink set name is not specified UplinkSet (required) The name of the shared uplink set to which the port belongs if the network name is not specified Speed (optional) Specifies the port speed for the port. Valid values are "Auto", "10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". If no connector is present on the uplink port, only "Auto" and "Disabled" can be configured as the speed. Speed restrictions apply. Role (optional) The role played by the port if the connection mode of the network or shared uplink set is selected as "Failover". Valid values are "Primary" and "Secondary". The default value is "Primary". If the uplink set contains an FCoE network, then the role property is not allowed. Examples ->set uplinkport enc0:1:2 Network=MyNetwork Speed=1Gb Changes the port speed of a network port ->set uplinkport enc0:2:1 Network=MyNetwork Speed=Disabled Disables a specific port that belongs to a network ->set uplinkport enc0:2:4 UplinkSet=MyUplinkSet Speed=Disabled Disables a specific port that belongs to a shared uplink set ->set uplinkport enc0:2:4 Network=MyNetwork Role=Secondary Modifies the role of the network uplink port with the connection mode on the network or the shared uplink set as "Failover" to take the Secondary port role Item Description show uplinkport Display all Ethernet module uplink ports known to the domain. If the port is a member of a network or a shared uplink set, it appears. If the port is unlinked and no see "Port status conditions (on page )." Syntax show uplinkport Parameters
The port ID is in the format
connectivity exists, the cause is displayed. For more information about possible causes,
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem