Configbackup – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 21

Command line 21
Any user- or VC-defined MAC addresses, WWNs, and logical serial numbers will not appear in the output
to avoid duplicating these values.
Supported actions: help, show
Item
Description
show config
Generate a configuration script from the running domain.
Syntax
show config
Example
->show config
Displays the configuration script for the running domain
configbackup
Manage the domain configuration file.
Supported actions: help, restore, save
CAUTION:
Do not restore a configuration backup file by using a file from another domain and
including the property to ignore the enclosure serial number. Restoring a Virtual Connect domain
configuration from a backup file that was created on another Virtual Connect domain is not
supported and can cause serious faults within this and other Virtual Connect Domains within the
environment. The restore selection and configuration files should only be used to restore the same
previously existing domain.
Item
Description
restore configbackup Transfer a configuration file from a remote TFTP or FTP server and restore the
configuration. Be sure that the domain state is IMPORTED before attempting to
restore the configuration.
Syntax
restore configbackup [-quiet][-maskEncryptKey]
address= ftp://user:password@ipaddress/[filename]> [encryptionkey= [ignoreenclosureid= [ignorefwversion= Option quiet (optional) Suppresses user confirmation prompts maskEncryptKey (optional) Enables you to interactively specify the encryption key as a masked string at the command prompt Properties Address (required) A valid IP address of a TFTP or FTP server with user name and password (where needed) and the name of the configuration backup file. If not specified, the default file name is "vc-config-backup". The file path specified is treated as permissions are appropriate for a successful transfer. EncryptionKey (optional) A password used to encrypt the configuration backup file IgnoreEnclosureID (optional) Restores a configuration that was generated on another enclosure. Valid values are "true" and "false". The default value is "false". When the value is set to "false", the configuration generated on another enclosure is rejected.
relative to the login directory for the user on the FTP server. Be sure that the
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem