HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 77
Command line 77
Item
Description
NetworkName
(required)
The name of an existing network to modify
Option
Quiet (optional) Suppresses user confirmation prompts during network creation and modification. This
option is used mainly in automated scripting scenarios.
Properties
Name (optional)
The new name of the network
State (optional) Enables or disables the network. Valid values are "Enabled" and "Disabled".
SmartLink
(optional)
Enables or disables the SmartLink capability for a network. Valid values include
"Enabled" and "Disabled". This property is not allowed for an FCoE network.
SmartLink cannot be modified unless one or more ports are added to the network.
NativeVLAN
(optional)
Enables or disables the network to act as a native VLAN. Valid values are "Enabled"
and "Disabled". The default value is "Disabled". This property can be configured only
if it is applied to a shared Ethernet network.
Private
(optional)
Enables or disables the network to act as a private network. Valid values are "Enabled"
and "Disabled". The default value is "Disabled". This property is not allowed for an
FCoE network.
Nags (optional)
Modifies the network access groups of which this network is a member. The specified
network access groups replace the original network access groups. If no network
access groups are specified, the network access groups are not changed.
VLanID (optional) Modifies the VLAN ID of the network if it belongs to a shared uplink set that has not
been configured
ConnectionMode
(optional)
Specifies the connection type that is formed when multiple ports are added to the
network. Valid values include "Auto" and "Failover". The default value is "Auto". This
property is not allowed for an FCoE network.
VLanTunnel
(optional)
Enables or disables VLAN tag tunneling. Valid values are "Enabled" and "Disabled".
If enabled, VLAN tags are passed through the domain without any modification. If
disabled, all tagged frames are discarded. This property is not allowed for an FCoE
network.
If multiple networks are configured on any server port, this option cannot be modified.
PrefSpeedType
(Optional)
The default connection speed for any Ethernet connection attached to this network.
Valid values include "Auto" and "Custom". "Custom" enables you to configure the
preferred speed. The default value is "Auto".
PrefSpeed
(Required if
PrefSpeedType is
"Custom")
The connection speed for any Ethernet connection attached to this network. Valid
values range from 100Mb to 10Gb in 100Mb increments.
MaxSpeedType
(Optional)
The maximum connection speed for any Ethernet connection attached to this network.
Valid values include "Unrestricted" and "Custom". "Custom" enables you to configure
the preferred speed. The default value is "Unrestricted".
MaxSpeed
(required if
MaxSpeedType is
"Custom")
The maximum connection speed for any Ethernet connection attached to this network.
Valid values range from 100Mb to 10Gb in 100Mb increments.
LacpTimer
(optional)
Specifies the network LACP timer. Valid values are "Domain-Default", "Short", and
"Long". This property can be specified only if the network is not a network associated
with a Shared Uplink Set, or the ConnectionMode property value is "Auto". The default
value is "Short".
Nags (optional)
The Network Access Group(s) the network belongs to. The default is Default Network
Access Group, a list of Network Access Group names separated by comma. The
Network Access Groups should be in quotation marks if there are spaces in the list. This
property is not allowed for an FCoE network.
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem