Fcoe-connection – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 41
Command line 41
Item
Description
BootPort
(Required if the Boot Priority is
either Primary or Secondary,
otherwise optional)
The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format
NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.
BootLun
(Required if the Boot Priority is
either Primary or Secondary,
otherwise optional)
The LUN of the volume used for SAN boot. Values include integers from 0 to
255 or 16 hex digits (HP-UX only).
Examples
->set fc-connection MyProfile 1 Fabric=SAN_5
Changes the fabric of an FC SAN fabric connection
->set fc-connection RedProfile 2 Fabric=""
Sets an FC SAN fabric connection to "Unassigned"
->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection
->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection
->set fc-connection BlueProfile 1 BootPriority=Primary
BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters
Item
Description
show fc-connection
Display the FC SAN connections associated with the server profiles.
Syntax
show fc-connection [
Parameter
ConnectionID
(optional)
The ID of an existing FC SAN connection. The ID format is
Use
display all FC SAN connections in the domain.
Examples
->show fc-connection
Displays all FC SAN connections in the domain
->show fc-connection Profile1:*
Displays all FC SAN connections of a profile named Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of a profile named Profile1
fcoe-connection
Manage FCoE connections.
Supported actions: add, help, remove, set, show
Item
Description
add fcoe-connection
Add a new FCoE connection to an existing server profile. For more information,
see "General requirements for adding FC or FCoE connections (on page
)."
If the QoS type for the domain is set to "CustomNoFcoe", a "cannot add fabric
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem