Uplinkport – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 121

Command line 121
Item
Description
Timeout (optional)
The time in seconds by which a server response must be received before a new
request is made. The valid range of values is from 1 to 600 seconds. The default
timeout is 10 seconds.
SecondaryServer
Address (optional)
The IP address or host name of the secondary TACACS server used for
authentication
SecondaryPort
(optional)
The TCP port to use for TACACS communication. Valid values include a valid port
number between 1 and 65535. The default TCP port number is 49.
SecondaryServerKey
(optional)
The plain-text string used to encrypt user details exchanged with the secondary
TACACS server. It must match the server key configured for this VC on the
secondary server. TACACS authentication will not work if the server key is blank
or null.
SecondaryTimeout
(optional)
The timeout value in seconds for TACACS communication with the secondary
server
LoggingEnabled
(optional)
Enables or disables command logging on the TACACS+ server. Valid values
include "true" and "false".
Examples
->set tacacs -test Enabled=true ServerAddress=192.168.0.27
->set tacacs -test Enabled=true Server Address=2001::40
Tests the TACACS+ configuration changes without applying them
->set tacacs Enabled=true ServerAddress=192.168.0.124
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com
SecondaryServerKey=test456
->set tacacs Enabled=true ServerAddress=2001::70
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com
SecondaryServerKey=test456
Enables TACACS+ authentication for users
->set tacacs LoggingEnabled=true
Enables TACACS server logging
Item
Description
show tacacs
Display the Virtual Connect TACACS+ authentication settings.
Syntax
show tacacs
Example
->show tacacs
Displays TACACS+ information
uplinkport
Manage interconnect module uplink ports.
Supported actions: add, help, remove, set, show
Item
Description
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set.
Syntax
add uplinkport
UplinkSet=
[Speed=
[Role=
Parameter
PortID (required) The ID of an uplink port to add. The ID is a combination of the enclosure name,
interconnect bay, and port number in a single descriptor. The port ID for a network or
- Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem