Badger Meter ReadCenter User Manual
Page 57
![background image](/manuals/371200/57/background.png)
From Reader
The From Reader tab has information
from the person or collection device that
reads the meter Fields are filled in after
collection devices are unloaded
Field Name
Type
Size Description
Present Read
Numeric
—
Meter reading for billing purposes (See the Read Value Note on
for
adjustments that may have been made to radio and touch reads )
Read Date/Time
Date/Time
—
Date and time the meter reading was received
Read Type
N – Unread
R – Regular
H – High
L – Low
r – Regular with Inquiry
h – High with Inquiry
l – Low with Inquiry
—
Code received from the collection device that indicates the type of
reading that was acquired Refer to
Read Method
N – Unread
d – Manual
D – Interrogated
—
Code received from the collection device that indicates whether the
reading was acquired and how it was acquired Refer to
Trouble Code
Code Table
50
Code entered by the meter reader into the collection device that alerts the
ReadCenter Analytics operator to problems with the meter being read
Read Code 1
Code Table
50
Code entered by the meter reader into the collection device to supply
information related to the meter being read to the ReadCenter Analytics or
Analytics Mobile operator
Read Code 2
Code Table
50
Code entered by the meter reader into the collection device to supply
information related to the meter being read to the ReadCenter Analytics or
Analytics Mobile operator
Read Code 3
Code Table
50
Code entered by the meter reader into the collection device to supply
information related to the meter being read to the ReadCenter Analytics or
Analytics Mobile operator
Exception
See Appendix
—
Code received from the collection device that indicates there is an alert
condition in the reading endpoint
Reader Initials
Alphanumeric
10
Initials entered into the collection device by the meter reader when
beginning the reading process The meter reader’s initials are automatically
associated with each meter reading If the reading is received via a gateway,
Reader Initials field will display AUTO
User Manual
Page 57
June 2014