Screen Layout for Other Reports
For all reports except History, the following descriptions apply
•
The middle section of the Gateway Reading Reports screen is blank
•
The right side of the Gateway Reading Reports screen displays the report, which includes the individual account
information and the Meter Readings table
•
The Show History button in the tool bar can be used to run a History report for an account
•
Two text boxes are displayed in the bottom tool bar next to the Close button The left is blank The right contains the
number of records returned for the report selected
Status
When a report is run, status indicators display across the top of the report The box will be checked if the status was reported
by the endpoint at the time of the read In Preview mode, status is displayed as a single letter as shown in the Preview Status
column in the table below
Gateway Reading
Reports Status
Preview
Status
Description
Program
O
Endpoint received a program parameter change For example, it was reprogrammed via IR
Device
D
Device condition Endpoint reports an encoder error for ENC For ELCD, conditions are
indicated in the extended status as shown below
E-Series
HR-E LCD
Empty Pipe
Reverse Flow
Encoder Removal
Reverse Flow
Temp Limit
Leak
Temp Limit
Leak
Encoder Life
Encoder Programmed
Encoder Life
Encoder Programmed
No Usage
Sensor Error
No Usage
Magnetic Tamper
Tamper
T
Endpoint reports a tamper condition
Reverse
R
Endpoint reports the encoder measured flow in the reverse direction
No Use
U
Endpoint reports no usage
Leak
L
Endpoint reports a potential leak condition
Low Batt
A
Endpoint reports that its estimated battery life is low
Primary
Y
The Primary indicator is only checked for the endpoint current reads Current reads are
collected when the
Current Reads
schedule runs
Mobile
M
Endpoint read collected via mobile device
Usage Report Status
In addition to the status indicators listed above, the Usage report also has three additional columns—Max, Min, Usage—to
show the maximum, minimum and current usage as reported by the endpoint
Source
Except for the Usage report, the Source of the read is shown in the last column of the reports The following options
can display
•
Fixed: Current or Fixed: Historical which indicates the reading is from a gateway
Fixed: Current displays when the
Current Reads
schedule is run Fixed: Historical displays when the
Historical Reads
schedule is run
•
Mobile: Current or Mobile: Historical
which
indicates the reading is from a mobile collection device
Mobile Source indicators only display for customers with both fixed and mobile reading systems
OTE:
N
If the read Source is Mobile (Current or Historical), the number in the Gateway # column on the report is shown as “-1 “
User Manual
Page 29