Technical data – KROHNE IFC 300 Converter EN User Manual

Page 146

background image

8

TECHNICAL DATA

146

IFC 300

www.krohne.com

08/2010 - 4000069803 - MA IFC 300 R04 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Refer to technical data for the measuring sensor.

Ambient temperature

Depending on the version and combination of outputs.

It is a good idea to protect the converter from external heat sources such as direct

sunlight as higher temperatures reduce the life cycle of all electronic components.

-40…+65°C / -40…+149°F

Ambient temperatures below -25°C / -13°F, may affect the readability of the display.

Storage temperature

-50…+70°C / -58…+158°F

Pressure

Pressure

Pressure

Pressure

Medium

Refer to technical data for the measuring sensor.

Ambient pressure

Atmosphere: Height up to 2000 m / 6561.7 ft

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Electrical conductivity

Standard

Standard

Standard

Standard

All media except for water: ≥ 1 µS/cm

(also refer to the technical data for the measuring sensor)

Water: ≥ 20 µS/cm

TIDALFLUX 4000

TIDALFLUX 4000

TIDALFLUX 4000

TIDALFLUX 4000

All media: ≥ 50 µS/cm

(also refer to the technical data for the measuring sensor)

OPTIFLUX 7000

OPTIFLUX 7000

OPTIFLUX 7000

OPTIFLUX 7000

All media except for water: ≥ 0.05 µS/cm

(also refer to the technical data for the measuring sensor)

Water: ≥ 1 µS/cm

Physical condition

Conductive, liquid media

Solid content (volume)

Can be used up to ≤ 70% for OPTIFLUX and TIDALFLUX measuring sensors

The greater the solid content, the less accurate the measurements!

Gas content (volume)

Can be used up to ≤ 5% for OPTIFLUX and TIDALFLUX measuring sensors

The greater the gas content, the less accurate the measurements!

Flow

For detailed information, refer to chapter "Flow tables".

Other conditions

Other conditions

Other conditions

Other conditions

Protection category acc. to

IEC 529 / EN 60529

C (compact version) & F (field housing):

IP66/67 (acc. to NEMA 4/4X/6)

W (wall-mounted housing):

IP65/66 (acc. to NEMA 4/4X)

R (19" rack-mounted housing (28 TE) or (21 TE)):

IP20 (acc. to NEMA 1);

Use: Indoor only, level of pollution 2 and relative humidity < 75%

Installation conditions

Installation

For detailed information, refer to chapter "Installation conditions".

Inlet/outlet runs

Refer to technical data for the measuring sensor.

Dimensions and weights

For detailed information refer to chapter "Dimensions and weights".