7

SERVICE

94

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

1 Make sure that the gasket is on the flange connection.
2 Put the adaptor on the process connection.
3 Attach and tighten the 4 socket head screws with a 5 mm Allen wrench.
4 Put the OPTIWAVE 5200 signal converter on the adaptor. Make sure that the adaptor fully en-

gages in the mating part (signal converter).

5 Tighten the socket set screw at the bottom of the signal converter with a 5 mm Allen wrench.

Procedure 3: How to attach the OPTIWAVE 5200 signal converter

Figure 7-4: Procedure 3: How to attach the OPTIWAVE 5200 signal converter

INFORMATION!
The adaptor for the BM 70x process connection is available as a spare part. Send an order for
this part only or for the OPTIWAVE 5200 signal converter with the adaptor attached. For the order
code, refer to Order code on page 134

.