TECHNICAL DATA

8

115

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

8.5 Antenna selection

The graphs below show which antenna to select for the application based on:

• D, the measuring range,
• ε

r

, is the dielectric constant of the product being measured

Figure 8-16: Selection of antenna (graph of distance in m against ε

r

)

Figure 8-17: Selection of antenna (graph of distance in ft against ε

r

)

1 Tank height / Measuring range [m]
2 Tank height / Measuring range [ft]
3 ε

r

for storage tanks with smooth product surface

4 ε

r

for process tanks without agitator or foam

5 All antennas:

- DN80/3¨ and DN100/4¨ Metallic Horn antenna: only for use in a stilling well*
- Wave Guide antenna: maximum measuring range is 6 m / 19.68 ft

6 DN150/6¨ or DN200/8¨ Metallic Horn antennas in a stilling well* or DN200/8¨ Metallic Horn antenna
7 DN200/8¨ Metallic Horn antenna in a stilling well*

* A stilling well is equivalent to the Wave Guide antenna option or a bypass chamber