Safety instructions – KROHNE OPTIWAVE 5200 C_F EN User Manual
Page 9
SAFETY INSTRUCTIONS
1
9
OPTIWAVE 5200 C/F
www.krohne.com
07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
According to ETSI EN 302 372 (2006-04), the radiated power outside a metallic tank is less than -
30 dBm.
The device and the tank agree with Annex B of ETSI EN 302 372-1 if you obey the
regulations that follow:
• Install the device in a permanent position on a closed metallic tank, a reinforced concrete
tank or a structure with a closed space made of an equivalent material. Make sure that the
device is correctly attached. We recommend that you install the device on the top of the tank
and the antenna points down.
• Seal flanges and attachments with EMI/RFI shielding gaskets. This gasket is supplied as an
accessory. For the order code, refer to
Accessories
on page 144.
• Sight glasses must have a microwave-proof layer on them.
• Close all openings and process connections.
• Only approved personnel can install the device.
For data about how to install EMI/RFI shielding gaskets, refer to the instructions supplied with
this accessory.
The radio approval report is given on the DVD-ROM supplied with the device.
Figure 1-1: Radio approval information on the nameplate
1 CE sign
2 Notified body number (0682 = CETECOM ICT Services GmbH)
3 Class II identifier