beautypg.com

Description of hart interface, 2 basic-dd menu tree (details for settings), 1 measurements – KROHNE OPTIWAVE 5200 C_F EN User Manual

Page 128: 2 configuration and test, 3 diag/service, 4 access rights, 5 hart variables

background image

9

DESCRIPTION OF HART INTERFACE

128

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

9.9.2 Basic-DD menu tree (details for settings)

1 Measurements

1 Measurements

1 Level value

Rd

/ 2 Distance value

Rd

/ 3 Volume value

Rd

/ 4 Ullage value

Rd

/ 5 Reflection

value

Rd

2 Inputs/Outputs

1 PV

Rd

/ 2 PV Loop Current

Rd

/ 3 PV % rnge

Rd

2 Configuration and Test

1 Info.

1 Identification

1 Serial Number

Rd

/ 2 Converter Firmware Version

Rd

/

3 Sensor Firmware Version

Rd

/ 4 HMI Firmware Version

Rd

2 Output

1 Function I

Rd

/ 2 Output Range

Rd

/ 3 PV URV

Rd

/ 4 PV LRV

Rd

/ 5 Output Error Delay

Rd

2 Supervisor

1 Test

1 Test I

2 Basis Parameters

1 Tank Height / 2 Blocking Distance / 3 Time Constant /

4 Pipe Enabled / 5 Pipe Diameter / 6 Pipe Height /

7 Antenna Extension / 8 Antenna Type / 9 Distance Piece /

15 Length Unit (HART) / 16 Volume Unit (HART)

3 Signal Out

1 Function I / 2 PV LRV / 3 PV URV / 4 Output Range /
5 Output Error Delay / 6 Current Ouput Calibration

Cust

4 Application

1 Tank Type / 2 Tracking Velocity / 3 Esilon R Product /

4 Measuring Mode / 5 Overfill Detection / 6 Multiple

Reflection / 7 Empty Spectrum / 8 Record Empty Spectrum

5 Display

1 Language / 2 Display Length Unit / 3 Display Volume Unit

6 Conversion Table

1 Input table / 2 Delete table

7 Reset

1 Warm start / 2 Factory reset / 3 Reset Configuration

Changed flag

3 Diag/Service

1 Status

1 Standard status

1 Device status

Rd

/ 2 Write protect

Rd

2 Device-specific status

1 Device failures

1 Error

Rd

/ 2 Error

Rd

/

3 Error

Rd

2 Device warning

maintenance required

1 Warning

Rd

3 Device warning out of

specification

1 Warning

Rd

4 Info

1 Info

Rd

4 Access Rights

1 Access Level

(Access Not Granted)

2 Method Login

1 No Access (Log Out) / 2 Supervisor (Normal User) / 3 Service

3 Method Entry Code

5 HART variables

1 Poll addr / 2 Tag / 3 Hardware rev

Rd

/ 4 Software rev

Rd

/ 5 Descriptor / 6 Date /

7 Message / 8 Manufacturer

Rd

/ 9 Model

Rd

/ Dev id

Rd

/ Universal id

Rd

/ Fld dev rev

Rd

/

Num req preams

Rd

/ Num resp preams

Rd

/ Write protect

Rd

/ Production number

Rd

/

Final asmbly num

Rd

/ PV is / SV is / TV is / QV is