DESCRIPTION OF HART INTERFACE
126
OPTIWAVE 5200 C/F
www.krohne.com
07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
For installation data, refer to the "AMS Intelligent Device Manager Books Online" section "Basic
AMS Functionality > Device Configurations > Installing Device Types > Procedures > Install
device types from media".
9.6.2 Operation
9.6.3 Parameter for the basic configuration
Due to AMS requirements and conventions, there are differences when operating the signal
converter with AMS and operating using the local keyboard. The service menu parameters are
not supported and simulation is only possible for current outputs. The online help for each
parameter contains its function number as a reference to the local device display.
9.7 Field Device Tool / Device Type Manager (FDT / DTM)
A Field Device Tool Container (FDT Container) is a PC program used to configure HART
®
,
PROFIBUS and Foundation Fieldbus devices. To configure a device, an FDT container uses the
applicable Device Type Manager (DTM).
9.7.1 Installation
Before you operate the device, the Device Type Manager (Device DTM) must be installed in the
Field Device Tool Container. This .msi file is given on the DVD-ROM supplied with the device. You
can also download the file from our website. For installation and configuration data, refer to the
documentation that is supplied with the Device DTM on the DVD-ROM or in the "Downloads"
section of the website.
9.7.2 Operation
The DTM and the device's local display use almost the same procedures to operate the signal
converter. For more data, refer to
Operation
on page 61.
9.8 Process Device Manager (PDM)
The Process Device Manager (PDM) is a Siemens PC program designed to configure HART
®
and
PROFIBUS devices. Device Descriptions (DDs) are used to integrate different devices into the
PDM.
9.8.1 Installation
Install Device Description files supplied in the Device Install HART
®
PDM folder. This is
necessary for each type of field device that is used with SIMATIC PDM. This folder is available for
download from the website or on the DVD-ROM supplied with the device.
If you use PDM version 5.2, refer to PDM manual, section 11.1 - Install device / Integrate device
into SIMATIC PDM with Device Install.
If you use PDM version 6.0, refer to PDM manual, section 13 - Integrating devices.
INFORMATION!
For more data, refer to HART
®
menu tree for AMS on page 129
.