8
TECHNICAL DATA
102
OPTIWAVE 5200 C/F
www.krohne.com
07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
Beam angle (½ angle) of antenna
PP Wave Horn: 10°
PTFE Wave Horn: 10°
Metallic Horn DN80 / 3¨: 16° - used only in stilling wells
Metallic Horn DN100 / 4¨: 12° - used only in stilling wells
Metallic Horn DN150 / 6¨: 8°
Metallic Horn DN200 / 8¨: 6°
Wave Guide / stilling well: n/a - the radar signal is inside the tube.
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Display
LCD display
128 × 64 pixels in 8-step greyscale with 4-button keypad
Interface languages
3 language pack options (the language is given in the customer order):
1 English, French German and Italian
2 English, French,Spanish and Portuguese
3 English, Chinese (Mandarin), Japanese and Russian
Measuring accuracy
Resolution
1 mm / 0.04¨
Repeatability
±
1 mm / ±0.04¨
Accuracy
Standard: ±10 mm / ±0.4¨, when distance < 10 m / 33 ft;
±
0.1% of measured distance, when distance > 10 m / 33 ft
Option: ±5 mm / ±0.2¨, when distance < 10 m / 33 ft;
±
0.05% of measured distance, when distance > 10 m / 33 ft
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Reference conditions acc. to EN 61298-1
Temperature
+15...+25°C / +59...+77°F
Pressure
1013 mbara ±50 mbar / 14.69 psia ±0.73 psi
Relative air humidity
60% ±15%
Target
Metal plate in an anechoic chamber
Operating conditions
Temperature
Temperature
Temperature
Temperature
Ambient temperature
-40…+80°C / -40…+176°F
Ex: see supplementary operating instructions or approval certificates
Storage temperature
-50…+85°C / -58…+185°F
Process connection temperature
(higher temperature on request)
PP Wave Horn antenna:
PP Wave Horn antenna:
PP Wave Horn antenna:
PP Wave Horn antenna:
-20...+100°C / -4...+212°F
PTFE Wave Horn antenna:
PTFE Wave Horn antenna:
PTFE Wave Horn antenna:
PTFE Wave Horn antenna:
-50...+150°C / -58...+302°F
Metallic Horn antenna / Wave Guide antenna:
Metallic Horn antenna / Wave Guide antenna:
Metallic Horn antenna / Wave Guide antenna:
Metallic Horn antenna / Wave Guide antenna:
Standard: FKM/FPM (-40…+150°C (+200°C with an HT extension) /
-40…+302°F (+392°F with an HT extension));
Options: Kalrez
®
6375 (-20…+150°C (+250°C with an HT extension) /
-4…+302°F (+482°F with an HT extension)); PFA (-60°C…+130°C / -76…+266°F);
EPDM (-50...+130°C / -58...+266°F)The process connection temperature must agree
with the temperature limits of the gasket material.
Ex: see supplementary operating instructions or approval certificates
1