8

TECHNICAL DATA

102

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

Beam angle (½ angle) of antenna

PP Wave Horn: 10°

PTFE Wave Horn: 10°

Metallic Horn DN80 / 3¨: 16° - used only in stilling wells

Metallic Horn DN100 / 4¨: 12° - used only in stilling wells

Metallic Horn DN150 / 6¨: 8°

Metallic Horn DN200 / 8¨: 6°

Wave Guide / stilling well: n/a - the radar signal is inside the tube.

Display and user interface

Display and user interface

Display and user interface

Display and user interface

Display

LCD display

128 × 64 pixels in 8-step greyscale with 4-button keypad

Interface languages

3 language pack options (the language is given in the customer order):

1 English, French German and Italian

2 English, French,Spanish and Portuguese

3 English, Chinese (Mandarin), Japanese and Russian

Measuring accuracy

Resolution

1 mm / 0.04¨

Repeatability

±

1 mm / ±0.04¨

Accuracy

Standard: ±10 mm / ±0.4¨, when distance < 10 m / 33 ft;
±

0.1% of measured distance, when distance > 10 m / 33 ft

Option: ±5 mm / ±0.2¨, when distance < 10 m / 33 ft;
±

0.05% of measured distance, when distance > 10 m / 33 ft

Reference conditions acc. to EN 61298-1

Reference conditions acc. to EN 61298-1

Reference conditions acc. to EN 61298-1

Reference conditions acc. to EN 61298-1

Temperature

+15...+25°C / +59...+77°F

Pressure

1013 mbara ±50 mbar / 14.69 psia ±0.73 psi

Relative air humidity

60% ±15%

Target

Metal plate in an anechoic chamber

Operating conditions

Temperature

Temperature

Temperature

Temperature

Ambient temperature

-40…+80°C / -40…+176°F

Ex: see supplementary operating instructions or approval certificates

Storage temperature

-50…+85°C / -58…+185°F

Process connection temperature

(higher temperature on request)

PP Wave Horn antenna:

PP Wave Horn antenna:

PP Wave Horn antenna:

PP Wave Horn antenna:

-20...+100°C / -4...+212°F

PTFE Wave Horn antenna:

PTFE Wave Horn antenna:

PTFE Wave Horn antenna:

PTFE Wave Horn antenna:

-50...+150°C / -58...+302°F

Metallic Horn antenna / Wave Guide antenna:

Metallic Horn antenna / Wave Guide antenna:

Metallic Horn antenna / Wave Guide antenna:

Metallic Horn antenna / Wave Guide antenna:

Standard: FKM/FPM (-40…+150°C (+200°C with an HT extension) /

-40…+302°F (+392°F with an HT extension));
Options: Kalrez

®

6375 (-20…+150°C (+250°C with an HT extension) /

-4…+302°F (+482°F with an HT extension)); PFA (-60°C…+130°C / -76…+266°F);

EPDM (-50...+130°C / -58...+266°F)The process connection temperature must agree

with the temperature limits of the gasket material.

Ex: see supplementary operating instructions or approval certificates

1